Metering guide
Read loudness and peaks without mixing them up.
A mix can keep the same peak level while becoming much denser. That’s why a single number rarely tells you enough. Loudness and peak meters describe different parts of the signal.
LUFS and RMS answer different questions
RMS describes average signal power over an averaging interval. LUFS uses a loudness measurement method with frequency weighting. The numbers are not interchangeable, and there isn’t a fixed correction that turns every RMS reading into LUFS.
A low-frequency change can move a raw power reading differently from a loudness reading. RMS values can also differ between plugins when their averaging windows differ. Use the same measurement method when you compare passes.
Choose the time window
Momentary loudness follows a 400-millisecond window, while short-term uses 3 seconds. Integrated loudness describes the measured program with the method’s gating. Use the shorter windows to follow changes within a track, and integrated loudness for the pass as a whole. The EBU R128 recommendation sets out the loudness-measurement framework.
If the peak barely changes while short-term loudness rises, the passage may be carrying more sustained energy. Listen to what changed. The reading can help you investigate density, but it cannot decide whether the result serves the track.
Read sample peak and true peak together
Sample peak is the highest stored sample amplitude. True peak estimates the signal’s peaks between samples after reconstruction. A file can therefore have a higher true-peak reading than its sample-peak reading.
A sample-peak value below 0 dBFS doesn’t guarantee that true peak stays below that level. Check the actual delivery specification if you need a limit; a streaming normalization reference is not automatically the right mastering target for every job.
Run a fresh pass in Meters
Insert Meters at the point you want to check. Press Reset meters, then play the required section. For a whole-track integrated value, start before the first sound and let the track finish. A reading from the chorus alone describes that pass, not the whole song.
Stop/resume keeps the measurement. Reset on seek can start a new pass after a DAW jump or loop. If the plugin reports a data gap, reset before relying on a new result. Meters passes audio through unchanged, so any gain or limiting adjustment happens elsewhere in your chain.
Questions before you choose
Can I convert RMS to LUFS with one fixed offset?
No. Frequency weighting, signal content and averaging affect the relationship. Compare like-for-like measurements instead of relying on one correction value.
Does a sample peak below 0 dBFS rule out a higher true peak?
No. True peak estimates reconstructed peaks between samples, so it can exceed the highest sample amplitude.
When is integrated loudness a whole-track value?
When the measurement pass covers the whole track. Reset before playback and include the full program, rather than reading only one section.
Does Meters change the level to reach a target?
No. Meters measures the stereo input and passes it through unchanged. It does not normalize, limit or loudness-match the audio.
Put Meters to work
Signup includes Cuekeeping plugin news, updates and offers. Complete free checkout to add the installers to your account. The plugin works offline without activation.
Related reading
Published by Cuekeeping. Product facts checked against the linked official sources on November 5, 2026.